How to Write an RFQ for Custom Metal Parts: Drawings, DXF/STEP Files and Tolerances
Published November 2026 · 10 min read · Buyer's Guide · Fabrication
The quality of a request for quotation (RFQ) decides the quality of the quotes you get back. A complete RFQ gets comparable prices in days. An incomplete one gets padded prices, long question loops, or parts that match the drawing but not what you needed. This guide lists what a metal parts RFQ must contain, which files to send (PDF, DXF, STEP), how to state tolerances with ISO 2768, and includes an RFQ builder that checks your request and writes it out for you.
• A good metal parts RFQ has 12 elements: part list, drawings, CAD files, material grade, thickness, tolerances, processes, surface finish, certificates, quantities, delivery terms and target date.
• PDF drawing = the legal reference (dimensions, tolerances, notes). DXF = 2D outline for laser, plasma and waterjet cutting. STEP = 3D model for bent, welded and machined parts.
• If no tolerance is given, suppliers assume their own. Write a general tolerance such as ISO 2768-mK in the title block and add tighter tolerances only on functional features.
• Ask for prices at 2–3 quantity levels (e.g. prototype, first batch, annual volume): unit price drops sharply once set-up costs are spread.
• Name the Incoterm and destination (e.g. FCA Istanbul, CIF Hamburg, DAP Lyon) or quotes will not be comparable.
Why the RFQ Decides Price, Lead Time and Quality
A manufacturer prices risk. Every missing detail in an RFQ — an unknown grade, an unstated tolerance, a finish described only as "painted" — is a risk the estimator either asks about or covers with margin. Busy shops often skip incomplete requests altogether and quote the clear ones first. The result is that two buyers sending the same part can receive very different prices and response times, simply because one RFQ was complete.
A complete RFQ also protects you after the order. When the drawing, files and specification are clear, the supplier's quote refers to them, and any deviation at inspection is the supplier's problem, not a matter of interpretation. This matters even more for cross-border sourcing, where questions and corrections cost days because of time zones and language.
The 12 Elements of a Complete Metal Parts RFQ
- 1. Part list (BOM) — part number, revision, description and quantity per assembly for every item. One line per part, even for simple brackets.
- 2. 2D drawing (PDF) — dimensioned drawing with title block, revision, material, finish and general tolerance. This is the document that governs inspection.
- 3. CAD files — DXF for flat cut parts, STEP for 3D parts. File names should match the part number and revision on the drawing.
- 4. Material grade with its standard — e.g. S355J2 (EN 10025-2), DC01 (EN 10130), 1.4404 / AISI 316L (EN 10088-2), EN AW-5754 H22. "Mild steel" or "stainless" alone is not a specification. See our steel grade equivalents table if your drawing uses ASTM, JIS or GB names.
- 5. Thickness or stock size — sheet thickness, bar diameter, profile size. State whether a substitute thickness (e.g. 2.5 mm for 2.4 mm) is acceptable.
- 6. Tolerances — a general tolerance class plus specific tolerances on critical features (holes, fits, flatness).
- 7. Processes — laser cutting, bending, welding, machining, threading, inserts, assembly. If you require a specific process (e.g. no plasma, machined not cut threads), say so.
- 8. Surface finish — hot-dip galvanizing (EN ISO 1461), zinc plating, powder coating with RAL code and minimum thickness, anodizing for aluminium, or raw/oiled. Include masking areas.
- 9. Certificates and inspection — material certificate type (usually EN 10204 3.1), dimensional report, first article inspection, coating thickness report, CE / EN 1090 where required.
- 10. Quantities — 2–3 quantity breaks and the expected annual volume, plus whether orders will be repeated.
- 11. Delivery terms — Incoterm, destination city or port, packaging requirements (pallets, crates, corrosion protection, labels).
- 12. Target date and quote deadline — when you need the quote, when you need samples, and when the first delivery is needed.
Which Files to Send: PDF, DXF or STEP?
Send a PDF drawing for every part, and add the CAD format that matches the process. Native files (SolidWorks, Inventor, Fusion) are useful as an extra, but not every shop runs the same software, so neutral formats are the safe choice.
| File | Used for | Good practice |
|---|---|---|
| PDF drawing | All parts — the governing document for dimensions, tolerances, material, finish and notes | Title block with part number, revision, material, thickness, finish, general tolerance and units. Mark critical dimensions. |
| DXF / DWG (2D) | Flat parts for laser, plasma and waterjet cutting; flat patterns of bent parts | Scale 1:1 in millimetres, closed contours, no duplicate or overlapping lines, no dimensions or title block on the cutting layer, bend lines on a separate layer. One part per file. |
| STEP (.stp / .step) | Bent sheet metal, welded assemblies, machined and turned parts | Solid bodies (AP214 or AP242), not surfaces. For sheet metal, model with the real thickness and inside bend radius. |
| IGES / Parasolid | Older or alternative 3D exchange | Accepted by most shops, but STEP is preferred because it transfers solids more reliably. |
| Photos / sketches | Replacement parts with no drawing | Enough for a budget estimate only. Add key dimensions, a reference object for scale and the material, or send a sample for reverse engineering. |
Tolerances: Using ISO 2768 General Tolerances
Dimensions without an individual tolerance are controlled by the general tolerance written on the drawing. The most widely used reference in Europe and Türkiye is ISO 2768. Part 1 sets linear and angular tolerances in four classes — f (fine), m (medium), c (coarse) and v (very coarse). Part 2 sets geometric tolerances (straightness, flatness, perpendicularity, symmetry, run-out) in classes H, K and L. A title block note such as "ISO 2768-mK" means medium linear tolerances and class K geometric tolerances.
ISO 2768-1 permissible deviations for linear dimensions (mm):
| Class | 0.5–3 | >3–6 | >6–30 | >30–120 | >120–400 | >400–1000 | >1000–2000 | >2000–4000 |
|---|---|---|---|---|---|---|---|---|
| f (fine) | ±0.05 | ±0.05 | ±0.1 | ±0.15 | ±0.2 | ±0.3 | ±0.5 | – |
| m (medium) | ±0.1 | ±0.1 | ±0.2 | ±0.3 | ±0.5 | ±0.8 | ±1.2 | ±2 |
| c (coarse) | ±0.2 | ±0.3 | ±0.5 | ±0.8 | ±1.2 | ±2 | ±3 | ±4 |
| v (very coarse) | – | ±0.5 | ±1 | ±1.5 | ±2.5 | ±4 | ±6 | ±8 |
Values from ISO 2768-1. "–" means no general tolerance is defined for that range; give an individual tolerance. Check the current edition of the standard.
Practical rules for buyers:
- Choose the general class by process, not by habit. Class m suits most cut, bent and machined parts. Class c is often enough for large welded frames and structural items. Class f raises cost and should be reserved for precision machined parts.
- Tighten only what is functional. Fits, bearing seats, hole positions that align with other parts and sealing faces need individual tolerances. Everything else can follow the general class.
- Do not use ISO 2768 for fits. Shaft and hole fits need ISO 286 tolerance symbols (e.g. Ø20 H7) or explicit limits.
- Bent parts accumulate error. Each bend adds variation, so dimension bent parts from a functional datum and avoid chains of tight tolerances across several bends.
- Welded assemblies distort. If flatness or hole positions matter after welding, say whether machining after welding is acceptable — it changes the quote.
Material, Finish, Welding and Certificates
Specify the material as grade + standard + condition, for example S355J2+N, EN 10025-2 or 1.4301 2B, EN 10088-2. If a local equivalent is acceptable, say so in the RFQ: Turkish mills and service centres stock EN grades, and allowing an equivalent can shorten lead time. For coated sheet, give the coating class (e.g. DX51D+Z275); our galvanized grades guide explains the notation.
| Topic | What to write in the RFQ | Example |
|---|---|---|
| Hot-dip galvanizing | Standard and any minimum coating thickness above the standard | Hot-dip galvanized to EN ISO 1461 |
| Powder coating | Colour code, gloss, minimum dry film thickness, pre-treatment | RAL 7016, matt, min. 80 µm, zinc phosphate pre-treatment |
| Welding | Weld symbols on the drawing, quality level, structural requirements | Welds to ISO 5817 level C; EN 1090-2 EXC2 for load-bearing parts |
| Threads | Thread standard, size, depth, cut or formed, inserts | M10 × 1.5, through; PEM nuts M6 on 4 positions |
| Material certificate | Certificate type per EN 10204 | EN 10204 3.1 for all steel parts |
| Inspection | Reports required before shipment | First article report with all drawing dimensions; coating thickness report |
Quantities, Delivery Terms and Customs Details
Set-up time — programming, nesting, tooling, fixtures, first-off inspection — is a fixed cost per batch. Asking for several quantities shows you where the price curve flattens and helps you choose an order size. A typical request is prototype (5–10 pcs), first batch, and annual volume, with a note on how often you expect to call off.
Always name an Incoterm (Incoterms 2020) and the exact place: EXW or FCA (factory or forwarder in Türkiye), FOB or CIF (sea freight, named port), DAP or DDP (delivered to your site). Add packaging needs, such as export pallets, wooden crates, VCI film for raw steel, or labels with your part numbers.
For imports into the EU, many fabricated parts fall under HS 7308 or 7326 (see our HS code guide for fabricated steel parts), and iron and steel articles in these headings are within the scope of CBAM. Asking the supplier for the HS code and embedded emissions data in the quote saves time at customs.
RFQ Builder: Check Your Request and Generate the Text
Fill in what you know. The tool scores how complete your RFQ is, lists what is missing, and writes a structured RFQ text you can paste into an email or our quote form.
Processes
Files attached
The tool runs in your browser. The Send button copies the text into our contact form; nothing is sent until you submit the form.
Common RFQ Mistakes and How to Avoid Them
| Mistake | What happens | Fix |
|---|---|---|
| "Steel, 3 mm" with no grade | Supplier quotes the cheapest grade (often S235 or DC01); strength or weldability may be wrong | Grade + standard, e.g. S355MC EN 10149-2 |
| No general tolerance | Supplier applies its own shop standard; disputes at inspection | ISO 2768-mK (or your class) in the title block |
| Everything toleranced tightly | Higher price, fewer bidders, more rejects | Tight tolerances only on functional features |
| DXF and PDF from different revisions | Parts cut to the wrong outline | Revision letter in all file names; state which document governs |
| "Painted" or "coated" | Wrong system, colour or thickness | Standard + colour + thickness, e.g. RAL 9005, 80 µm powder |
| Single quantity only | No view of price breaks; over- or under-ordering | 2–3 quantity breaks + annual volume |
| No Incoterm | Quotes with and without freight cannot be compared | Incoterm + named place |
| Certificates requested after the order | 3.1 certificates cannot always be produced retroactively | State certificate type in the RFQ |
How Steeling.net Handles Your RFQ
Steeling.net connects international buyers with vetted Turkish manufacturers for laser cutting, CNC bending, CNC machining, welded fabrication and steel materials. You send your RFQ once; we check it for missing information, match it with manufacturers that have the right machines and certifications, and coordinate the quotes, samples and delivery. Since 2023 we have handled more than 1,100 quotation requests from over 90 countries. There are no fees for buyers.
To estimate material weight and freight for your parts before you request a quote, use our steel weight calculator.
Frequently Asked Questions
What should an RFQ for metal parts include?
A complete RFQ includes a part list with revisions, a dimensioned PDF drawing, CAD files (DXF for flat parts, STEP for 3D parts), material grade with its standard, thickness, general and critical tolerances, required processes, surface finish, certificates and inspection reports, two or three quantity levels, the Incoterm and destination, and the target dates.
Should I send DXF or STEP files to a manufacturer?
Send DXF files for flat parts that are only cut (laser, plasma or waterjet), and STEP files for bent, welded or machined parts. In both cases add a PDF drawing, because the drawing carries tolerances, material, finish and notes that CAD files do not.
What does ISO 2768-mK mean on a drawing?
It means that all dimensions without an individual tolerance follow ISO 2768-1 class m (medium) for linear and angular dimensions and ISO 2768-2 class K for geometric tolerances such as flatness, straightness and perpendicularity. For example, a 50 mm dimension in class m may deviate by ±0.3 mm.
Do I need a drawing for laser cutting?
For simple flat parts, a clean 1:1 DXF in millimetres plus the material grade, thickness, quantity and general tolerance is often enough. A PDF drawing is still recommended when some features need tighter tolerances, when the part has threads or countersinks, or when the parts will be inspected against a specification.
How many quantities should I ask a supplier to quote?
Ask for two or three quantity levels, for example a prototype quantity, a first production batch and the expected annual volume. Set-up costs are fixed per batch, so the unit price can fall substantially between small and larger quantities.
Which Incoterm should I use when buying metal parts from Türkiye?
It depends on who arranges freight. FCA or EXW suits buyers with their own forwarder; FOB or CIF is common for sea freight to a named port; DAP or DDP suits buyers who want delivery to their site. Name the exact place with the Incoterm so that quotes from different suppliers can be compared.
Send drawings, DXF/STEP files, material, finish, quantities and destination. Steeling.net checks the request and returns quotes from qualified Turkish manufacturers. There are no fees for buyers.
Request a Quote →