C, Z and Omega Purlins: Sizes, Weights, Spacing and How to Choose

Published November 2026  ·  9 min read  ·  Technical Reference  ·  Roof & Facade Profiles

Purlins carry the roof and wall cladding of almost every steel building, and they are often the largest item in a building's secondary steelwork. Choosing between C, Z and omega sections, and getting the size, thickness and spacing right, affects both safety and steel tonnage. This guide explains the differences between the three profiles, gives weight tables for common sizes, shows typical spacing and span ranges, and lists what to specify when you order.

Quick answers
• C purlins: simple single spans, wall girts, framing around openings, end bays.
• Z purlins: lapped or continuous roofs with spans of about 5–9 m. Z sections nest into each other at supports, which makes the purlin line act as a continuous beam.
• Omega (hat) sections: secondary battens, spacers between purlins and cladding, ventilated facades and solar mounting rails.
• Typical material: pre-galvanized S350GD+Z275 to EN 10346, thickness 1.5–3.0 mm.
• Design standard: EN 1993-1-3 (Eurocode 3, cold-formed members).

What Are Purlins?

Purlins are horizontal members that span between the main rafters or trusses of a building and support the roof sheeting. The same sections used on walls are called girts or side rails. Modern purlins are cold-formed: galvanized steel strip is roll-formed into a C, Z or omega shape. Roll forming makes them much lighter than hot-rolled sections such as IPE beams or UPN channels for the same job, and it allows them to be cut and punched to exact lengths on the production line.

C vs Z vs Omega: Comparison

C purlinZ purlinOmega (hat) section
ShapeWeb with two flanges on the same side, with stiffening lipsWeb with flanges on opposite sides, often slightly unequal, with lipsHat shape: two webs, a top flange and two outward flanges
Structural systemSingle span, or sleeved at supportsLapped or continuous over supportsShort spans or continuous support
Typical spanUp to about 6 mAbout 5–9 m (lapped)About 0.6–2 m
Main advantageSimple to detail and install. Flat back for walls and openings.Lowest steel weight on multi-bay roofs. Easy to transport because sections nest.Stable on its own. Creates a uniform cavity behind cladding.
Typical useWall girts, door and window framing, mezzanines, small roofsIndustrial and warehouse roofs, agricultural buildingsFacade battens, sandwich panel spacers, solar rails, ceiling sub-frames

Why Z purlins save steel on multi-bay roofs

A Z section can be rotated and slid into the next Z section, so the two purlins lap over each support. In the lap zone the cross-section is doubled exactly where the bending moment is highest. The whole purlin line then works as a continuous beam, which reduces the maximum moment and deflection compared with a chain of single-span C purlins. On a roof with several equal bays, this usually allows a smaller or thinner section.

C sections cannot nest in the same way. They are used as single spans, or joined with a sleeve or a bolted splice, and they are preferred wherever a flat back face is useful, for example on walls and around openings.

C and Z Purlin Weight Table

C and Z purlins with the same height, flange width and lip size have practically the same weight and the same section modulus about the strong axis. The table below gives the theoretical steel weight for common sizes and thicknesses. Dimensions are h × b × c: height × flange width × lip length.

Size h × b × c (mm)1.5 mm
kg/m
2.0 mm
kg/m
2.5 mm
kg/m
3.0 mm
kg/m
Wel,y at 2.0 mm
cm³
Wel,y at 2.5 mm
cm³
100 × 50 × 152.643.494.325.1314.417.6
120 × 50 × 202.993.964.915.8418.823.2
140 × 60 × 203.464.585.696.7825.931.9
150 × 65 × 203.704.906.087.2529.836.8
175 × 65 × 203.995.296.577.8436.645.2
200 × 70 × 204.405.847.268.6745.756.5
225 × 75 × 204.826.397.959.4955.769.0
250 × 75 × 205.116.788.4410.0864.279.5
300 × 80 × 255.937.889.8111.7387.6108.6
350 × 90 × 256.768.9811.1913.38115.5143.2

Weights are calculated from nominal dimensions (centreline method, steel density 7,850 kg/m³). A Z275 zinc coating adds about 1–2%. Wel,y is the gross elastic section modulus. Design resistance to EN 1993-1-3 uses the lower effective section, so use the manufacturer's load tables or a structural calculation. Exact profile dimensions vary between roll-forming lines.

Weight Calculator

Typical Omega (Hat) Section Sizes

Size h × a × s (mm)1.0 mm
kg/m
1.5 mm
kg/m
2.0 mm
kg/m
30 × 30 × 200.991.461.92
40 × 40 × 201.221.812.39
40 × 60 × 251.462.172.86
50 × 50 × 251.542.283.01
60 × 60 × 301.852.763.64

Dimensions: height × top flange width × side flange width. Omega sections are produced in many custom sizes, so confirm the exact dimensions with the manufacturer.

Purlin Spacing and Span: Typical Ranges

Spacing is set by the cladding, and span is set by the frame spacing of the building. The figures below are typical ranges for preliminary planning only.

Roof or wall coveringTypical purlin spacingWhat decides it
Trapezoidal steel sheet, 0.5–0.7 mm1.2–2.0 mSheet profile height and thickness, snow and wind load
Sandwich panels, 40–100 mm1.5–3.0 mPanel manufacturer's load and span tables
Fibre cement or polycarbonate sheets0.9–1.4 mSheet manufacturer's limits
Wall cladding (girts)1.5–2.5 mWind pressure and suction, openings

For the purlin itself, a common starting point is a section height of about span / 30 to span / 40 for lapped Z purlins. For a 6 m frame spacing this gives about 150–200 mm, and for a 7.5 m spacing about 200–250 mm. Single-span C purlins need a deeper or thicker section for the same span.

Engineering note: Purlins also restrain the rafters against buckling, and they are sensitive to wind suction, when the unrestrained bottom flange is in compression. Sag rods or anti-sag bars, cleats and the fixing of the cladding all affect capacity. The final size and thickness must come from a calculation to EN 1993-1-3 or from the manufacturer's verified load tables.

Material and Corrosion Protection

Most purlins are roll-formed from continuously hot-dip galvanized strip to EN 10346. The steel grade sets the strength, and the coating designation sets the corrosion protection:

  • Steel grades: S280GD, S320GD and S350GD are most common. S390GD and S450GD allow thinner sections for the same load.
  • Zinc coating: Z275 (275 g/m² total on both sides) is the usual standard for roofs and walls in enclosed buildings. Z350 or higher is used for more aggressive environments.
  • Zinc-magnesium (ZM): ZM coatings such as ZM310 offer better corrosion resistance at a lower coating weight. They are often chosen for agricultural buildings, coastal sites and solar structures.
  • Hot-dip galvanizing after fabrication to EN ISO 1461 is an option for very aggressive environments, but it is rarely used for thin purlins.

Choose the coating by the corrosivity category of the site (C2 to C5 under ISO 9223). Livestock buildings, coastal areas and chemical plants need more than the standard Z275.

How to Order C, Z and Omega Purlins

  • Profile type and dimensions: h × b × c and thickness, for example Z 200 × 70 × 20 × 2.0 mm. For Z purlins, state if the flanges are unequal (for lapping).
  • Steel grade and coating: for example S350GD+Z275 or S350GD+ZM310 to EN 10346.
  • Cut lengths per piece, including lap lengths for Z purlins.
  • Punching: hole diameter, positions and pattern for cleats, sleeves and sag rods. Send a drawing or a cutting list.
  • Accessories: cleats, sleeves, sag rods, bracing and bolts. Order them together to avoid fit-up problems on site.
  • Quantity in metres, pieces or tonnes. Use the calculator above to convert.
  • Certificates: EN 10204 3.1 for the coil, and CE marking under EN 1090 where required.
  • Packing: bundle size and weight limits, protection against white rust during sea freight.
Classification tip: Cold-formed C, Z, U and omega sections made from flat-rolled steel are classified under CN 7216 61 10. Purlins that are punched and supplied as parts of a building kit may be classified under HS 7308. Our HS codes guide explains the difference. Both headings are covered by the EU CBAM.

Sourcing Purlins from Türkiye

Türkiye has a large roll-forming industry serving construction markets in Europe, the Balkans, the Middle East and Africa. Turkish producers roll C, Z, Sigma and omega sections from galvanized and ZM coils in thicknesses up to about 3–4 mm, and punch and cut them to the customer's cutting list in one operation. Short transit times by truck to the Balkans and Central Europe make Türkiye a practical source for project deliveries.

See our roof and facade profiles range. For wall framing and modular buildings, see light gauge steel (LGS) C and U profiles. For the main frame, see our HEA and HEB tables.

Frequently Asked Questions

What is the difference between C and Z purlins?

A C purlin has both flanges on the same side of the web, while a Z purlin has its flanges on opposite sides. Z purlins can be nested and lapped over supports, so they work as continuous beams and are more efficient on multi-bay roofs. C purlins are simpler and are preferred for single spans, wall girts and framing around openings.

What is an omega purlin used for?

Omega (hat) sections are used as secondary battens and spacers, for example between purlins and sandwich panels, behind facade cladding, for ventilated facades and as solar panel mounting rails. They are stable on their own because of their closed-top shape.

What is the standard spacing of roof purlins?

Purlin spacing usually ranges from about 1.2 to 2.0 m for trapezoidal steel sheets and from 1.5 to 3.0 m for sandwich panels. The exact spacing comes from the cladding manufacturer's load and span tables for the snow and wind loads on the site.

How much does a Z200 purlin weigh?

A Z 200 × 70 × 20 purlin in 2.0 mm steel weighs about 5.8 kg per metre. In 2.5 mm it weighs about 7.3 kg per metre. Exact weights depend on the manufacturer's profile dimensions.

What steel grade are purlins made from?

Purlins are usually roll-formed from hot-dip galvanized strip to EN 10346, most often S350GD with a Z275 zinc coating. Higher grades such as S450GD, and zinc-magnesium coatings, are also common.

What is the HS code for C and Z purlins?

Cold-formed C, Z, U and omega sections obtained from flat-rolled products are classified under CN 7216 61 10. Purlins supplied punched as parts of a building structure may fall under HS 7308. Confirm the code with your customs broker.

Need C, Z or omega purlins?

Send your cutting list or drawings. Steeling.net returns offers from Turkish roll-forming manufacturers for purlins in galvanized or ZM steel, punched and cut to length, with accessories. There are no fees for buyers.

Get a Free Quote →